Cardiology Equipment And Stores×Other Medical Diagnosis Equipments×Medical Equipment×

RAJENDRA INSTITUTE OF MEDICAL SCIENCE Tender Result

TENDER AWARD DETAILS

supply of cardiology implants at rims, ranchi- consumables (hospital / lab). -1.01 coronary diagnostic catheter for engagement of selective coronary ostium from femoral route item1 1.02 coronary diagnostic catheter for engagement of selective coronary ostium from radial route item2 1.03 coronary guiding catheter item3 1.04 014 cornonary guidewires 1.05 drug eluting stents 1.06 035 ptfe coronary catheter guidewire j tip 145 to 170 cm 1.07 pressure monitoring line 1.08 high pressure line 1.09 ptca kit with y connector, tuohy borst valve and 25 cm extension 1.1 indeflator for coronary angioplasy 1.11 coronary balloon catheter 1.12 unfractionated heparin 1.13 temporary pacing wire 6fr 1.14 vvir permanent implantable pacemaker 1.15 double lumen balloon dilatation catheter of various sizes for percutaneous transmitral mitral commisurotomy with all accessories (round wire, septal dilator, j-wire for ptmc balloon, femoral svenous sheath) 1.16 8 fr mullins sheath for trans-septal access 1.17 032 ptfe j tipped wire 1.18 transeptal puncture needle 70 cm long, curved tip, 18 gauge with a distal taper to 21 gauge, preferably brockenbrough needle. 1.19 pigtail cardiac catheterisation catheter 6 fr 1.2 vascular sheath for radial artery cannulation 1.21 vascular sheath for femoral artery cannulation 2 hardware requirement for coronary angioplasty 2.01 coronary diagnostic catheter for engagement of selective coronary ostium from femoral route judkins left, judkins right similar curves from other manufacturers guide catheters to be provided in 6fr size various curves like 3, 3.5, 4 to be provided for the catheters wherever applicable 2.02 coronary diagnostic catheter for engagement of selective coronary ostium from radial route tiger catheter similar curves from other manufacturers guide catheters to be provided in 5fr size 2.03 coronary guiding catheter for engagement of selective coronary ostium judkins left, judkins right, extra back up guide for left, amplatz guide for left, amplatz guide for right or similar curves from other manufacturers guide catheters to be provided in 6fr and 7fr sizes various curves like 3, 3.5, 4 to be provided for the catheters wherever applicable 2.04 014 cornonary guidewires of standard length 175 to 190 cm : following types of ptca wires to be provided guide wires with tip load < 1 gram guide wires with tip load 1 to 3 grams guide wires with tip load > 6 grams guide wires with hydrophilic coating 2.05 drug eluting stents of various diameters ( 2.5 mm, 2.75 mm, 3.0 mm, 3.5 mm, 3.5 mm, 4 mm) and various lengths (12mm to 40mm, as provided my manufacturer) with the following specifications 014 ptca gudewire compatible monorail design everolimus, sirolimus or zotarolimus eluting strut thickness < 100 um cocr or ptcr based strut design 2.06 035 ptfe coronary catheter guidewire j tip 145 to 170 cm 2.07 pressure monitoring line 200 cm male to female 2.08 high pressure line male to female 120 cm with braided tubing with maximum pressure delivery of 1200 psi 2.09 ptca kit with y connector, tuohy borst valve and cm extension containing torquer for ptca wire and ptca wire insetion tool 2.1 indeflator for coronary angioplasy with maximum pressure capacity of 30 atm. 2.11 coronary balloon catheter for coronary angioplasty with following specifications 014 ptca wire compatible monorail design 140 cm length or more with maximum profile <2.5 fr compliant balloons with diameter 1.25mm, 1.5mm, 2mm, 2.5mm. 2.75mm. non compliant balloons with diameter 2.5mm, 2.75mm, 3mm, 3.5mm,4mm various lengths for both compliant (10mm, 12mm, 15mm) and non-compliant (8mm, 10mm, 12mm, 15mm) balloons to be provided. 2.12 unfractionated heparin 1000iu/ml 5 ml bottle 2.13 vascular sheath for radial artery cannulation 5 fr, 6 fr 2.14 vascular sheath for femoral artery cannulation 6 fr, 7 fr, 8 fr 3 hardware requirement for pacemaker implantation 3.01 temporary pacing wire 6fr 3.02 vvir permanent implantable pacemaker us fda approved pacemaker with lead and accessories. all single chamber modes and basic multi-programmable parameters with preferably autosensing and auto capture/output management facilities. must have ventricular capture management. monitor the integrity of lead and switch polarity in case of issue 1.5 tesla mri compatible the size of lead should be 7f or less. the lead must be steroid eluting and should be both bipolar and unipolar configuration. must have both active and passive fixation endocardial leads available. must have rate response which allows rate profile optimization. company must provide at least one programmer exclusively to the department of cardiology rims ranchi. company must provide its trained technical person for each implantation and for follow up programming whenever required. company must quote only the latest model of devices commercially available. 4 hardware requirement for balloon mitral valvotomay (ptmc)

  • CITY & STATE
    Ranchi*, Jharkhand
  • RESULT ID:
    413408
  • CONTRACT AMOUNT:
    3.96 Lac
  • CONTRACT Date:
    28 Jul 2021
 Click to view detail
S. No.Seller NameOffered ItemParticipated OnMSE/MII StatusStatus
1Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
2Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
3Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
4Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
5Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
6Only Subscriber can view   Only Subscriber can viewOnly Subscriber can viewOnly Subscriber can viewQualified
 Click to view detail
Awarded Bids List
S.NoBid NumberBidder NameAwarded CurrencyAwarded Value
1Only Subscriber can viewOnly Subscriber can viewINROnly Subscriber can view
Qualified

SIMILAR TENDER RESULT