Aluminium Profile×Autoclave×Cabin×Cabinet×Distribution Board×Door×Door×Electrical Work×Laminar Flow×Lamps×Light and Bulb×Paint×Transformer×U P S×Led Luminaire×Electrical×Painting×

Government Of Uttar Pradesh

TENDERS DETAILS

supply of 1 pre-fabricated walls and celling panel pre fabricated modular construction shall be designed and constructed for exact size ,the pre-fabricated operating room with be free standing structure from composite free standing insulted steel wall panels the wall will be constructed using 1.0 mm ss 304 sheet panel in the front panels and 0.8 mm n ss-304 at the back pannel.the core between two panels will consist of rigid polyurethane foam which has been injected under high pressure with a minimum density of 40 k/ma the individual wall panel shall use the tongue and groove technology for joining two panels, no welding will be allowed the gaps between panels be suitably nied with metal filter/epoxy and sanded flush sqmtrs 133 the external walls of the room shall be constructed with solid bricks and mortar by the haspital as part of its scope of work. the inner surface walls shall be fixed to the brick wall with essential supports there natal be minimum possible cavity/gap in between the masonry and steel walls the total disance between inside and outside surface of or shall be vanable to suit architectss layout, out shall be suticient for lush mounting of the equipments the cavity between inner and outer wallls shell be left with minimum obstructions for passible addition of equipment and a later date and to enable services, pipes, conduits etc, to be run within the cavity all wall mounted equipment shall be flush mounted and sealed into theatre the wal panel design and construction shall allow tor installation and support of all equipment and provision ot openings required for the installations without altecting ngidity and strength access baxes shall be fitted to the rear of all the wall mounted equipments to enable maintenance to be carred out from outside the operating iuul all the sharp edges and corners shall be smooothened to avoid tactrial contamination. (tata/jindal/uttam galva or equilent) anti bacterial / anti fungal paint ( sikka/skk/jotun or equivalent) the internal surfaces of the ss-304 ot walls shoud be sprayad with water based, non- rellective liquid plastic, to a color approved be the architect a minimum dry film thickness of 300 micronas, these plastic coatings should overlap the floor covering ceiling system and door frames by 25mm provide a continuous sealed surface shade coating applied shoud be wafer resistant does not support bacteriological or fungal growth and is resistant to most chemicals commonly used in hospital departments the streile coating should remmains unaffected byh radiation and other ionizing rediation at levels in excesss of 1000 mred and is classified to class i when tested in accordance with the requirements specified under bs 478 part 7 1971 surface spread of flame test for materials the coating system should be easily maintained and can withsland-repeated cleaning with alkaline detergents antisepticfs and furnigation agents witout any degradation to the surface finish or performance, 2 laminar air flow celling nos 1 each modular ot shall have plan air ceiling. the plan air ceiling shall be constructed out of 2mm each extruded aluminum profiles, overall size 2400x2400min or larger as per actual layout, having six nos hepa filters with mpps efliciency of 99.99 and spot efticiency of 99.99 0.3 micron. the plenum should provide the required air volume to achieve the temperature pressure (15-30 pa) and humidity specified, and terminal velocity 90 to 120 fpm at the diffuser face air and light diffuser made of two layer of mono filament precision woven polyester for plan air celling to give a laminar flow of filtered air, it shall also provide a shadow less lighting system with control of the intensity of luminance by using high efficiency electronic fluorescent tubes am hepa fillters shall be factory tested and certified in accordance with international standard all edging include internal lighting and composite air/light diffuser air shall be diffuse into the theatre uniformmarly over the total area the laminar flow ceilling should also have illumination across the total area 3 automatic hermetically sealing doors (metaflex/rebbon or equivalent) i 2100x1500mm nos 1 ii 2100x1000mm nos 2 4 surgeon control panel nos 1 a the control panel will be user friendly and operation and maintenance will easy. the control panel shall be tiled membrane type can be configure incorporate all the service that operating theatre staff require. the fascia shall be made with super qualitry uv resistant sterlisble membrane. the membrane backing is made of 25mm thick aluminium that is not resistance. the connectoin between the surgeon conrol and the distribution board will be by a mulipleased system. the panel will contain and service file for a .time day clock b .time clapsed clock c .temperature / humudity indicator d .general ligting system e.medical gas alarm pannel f.hand free phone 5 led twin plate x ray viewer nos 1 the operation theatre shall be equiped with x ray viewing led screen designed to provide a high level of control luminance without ficker it shall be equiped with loaded dips to secure the x ray negative when it use 6 pressure relief dampers nos 1 pressure relief damper to be provided in thereafter to prevent users contamination of air from clean and dirty areas 7 anti static conductive flooring (gerflore/turket or equivalent) sqmtrs 48 8 storage cahinets nos 1 9 2 bay scrub sink nos 1 10 writing list board nos 1 11 peripheral light led (philips/cisco/havels or equivalent) nos 8 12 hatch box nos 1 13 electrical work inside the ot (polycab/finolex/havels or equivalent) job 1 air high voltage equipment is installed in a separate enclousers the remote cabinet house the operating lamp transformers main features relays electrical for all circuit when the operating theater. the wire used should be frish or frlsh pvc insulated. 14 medical gas pipelines work inside the ot (maxflow/rajco/mandev or equivalent) job 1 the medical gas pipeline inside the ot shall provide value box for 5 gases (o2,co2,n20,vacum, surgical air- 7 bar) outside each ot and shall bnng the medical gas pipeline inside the ot till celling pedants and provide nist connection for each gas pipe lines as per en737/htm standard or equivalent pedants shall connect flexible hose piping with medical gas piping by means of nist connections. the gas piping used for transporation should be as en 13348 en 1057 standards with copper filtings as per en 13348/3 en 1057 standard with copper fitting as per en 1254 standard. the outlets fitted for all the five gases in the pendants shall in conformity of htm standards. other accessories of medical gas pipelines like walled vacaume unit having 600 ml autoclave avail at 121 degree centigerate collection jar and theatre suction trolly having 2000 ml (2nos) autoclave avail 121 degree centigerate to be provided in each ot 15 ups system with isolation transformers 10 kva (apc/jms power/sai ups or equivalent) nos 1

  • CITY & STATE
    Lucknow,Uttar Pradesh
  • REF No:
    20574489
  • TENDER AMOUNT:
    Ref. Doc.
  • Last Date:
    06 Sep 2021
  • Tender Number Only Subscriber can view
  • Published By Only Subscriber can view
  • Website Name Only Subscriber can view
Archived
GeM tender portal

SIMILAR TENDER